亚洲一区欧美在线,日韩欧美视频免费观看,色戒的三场床戏分别是在几段,欧美日韩国产在线人成

酒糟主要成分含量的近紅外反射光譜快速分析
作者:
作者單位:

作者簡介:

通訊作者:

中圖分類號:

基金項(xiàng)目:

國家自然科學(xué)基金資助項(xiàng)目(31072062);科技部國際合作資助項(xiàng)目(2010DFA34540);歐盟第七框架資助項(xiàng)目(FPT—265702,QSAFFE)


Rapid Quantitative Determination of Main Components in Dried Distillers’ Grains by Near-infrared Spectroscopy
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 圖/表
  • |
  • 訪問統(tǒng)計
  • |
  • 參考文獻(xiàn)
  • |
  • 相似文獻(xiàn)
  • |
  • 引證文獻(xiàn)
  • |
  • 資源附件
  • |
  • 文章評論
    摘要:

    從全國21個省份收集78個代表性酒糟樣品,采用國標(biāo)方法測定了其成分含量并進(jìn)行了統(tǒng)計分析,結(jié)果顯示粗纖維、粗灰分和粗蛋白3種成分質(zhì)量分?jǐn)?shù)分布范圍分別為1.60%~37.54%、0.74%~26.85%和12.01%~38.69%,標(biāo)準(zhǔn)偏差分別為8.33%、5.21%和7.11%,樣品成分含量差異較大。利用NIRS建立了其粗纖維、粗灰分和粗蛋白質(zhì)量分?jǐn)?shù)的定量分析模型,定標(biāo)決定系數(shù)分別為0.98、0.91和0.96,定標(biāo)標(biāo)準(zhǔn)誤差分別為1.19%、1.58%和1.61%,驗(yàn)證決定系數(shù)分別為0.98、0.92和0.96,預(yù)測標(biāo)準(zhǔn)誤差分別為1.20%、1.57%和1.60%,相對分析誤差分別為7.38、3.75和4.98,模型預(yù)測精度較高,可以用于實(shí)際檢測分析。

    Abstract:

    Dried distillers’ grains were rich in nutrition, which used as protein feed materials, and could give some benefit to supplement feed deficit and reduce feed cost. Totally 78 dried distillers’ grains samples were collected from 21 provinces of China. Crude fiber, crude ash and crude protein contents were detected in laboratory by standard methods. The statistic analysis showed that the distribution range of crude fiber, crude ash and crude protein contents were 1.60%~37.54%, 0.74%~26.85% and 12.01%~38.69%, respectively, the standard distribution value of them were 8.33%, 5.21% and 7.11%, respectively. The big differences in components content were mainly caused by the remaining rice hull during drying and separating process. Quantitative evaluation models were established to determinate crude fiber, crude ash and crude protein content of dried distillers’ grains by NIRS methods. The results of NIRS analysis showed that this method could provide rapidly quantitative prediction for crude fiber, crude ash and crude protein contents in dried distillers’ grains, the coefficient of determination in calibration were 0.98, 0.91 and 0.96, respectively; the standard error in calibration were 1.19%, 1.58% and 1.61%, respectively; the coefficient of determination in validation were 0.98, 0.92 and 0.96, respectively; the standard error in validation were 1.20%, 1.57% and 1.60%, respectively, and the ratio of performance to standard deviation were 7.38, 3.75 and 4.98, respectively. The prediction values of these models are accurate.

    參考文獻(xiàn)
    相似文獻(xiàn)
    引證文獻(xiàn)
引用本文

周興藩,楊增玲,劉賢,黃光群,韓魯佳.酒糟主要成分含量的近紅外反射光譜快速分析[J].農(nóng)業(yè)機(jī)械學(xué)報,2012,43(3):103-107. Zhou Xingfan, Yang Zengling, Liu Xian, Huang Guangqun, Han Lujia. Rapid Quantitative Determination of Main Components in Dried Distillers’ Grains by Near-infrared Spectroscopy[J]. Transactions of the Chinese Society for Agricultural Machinery,2012,43(3):103-107.

復(fù)制
分享
文章指標(biāo)
  • 點(diǎn)擊次數(shù):
  • 下載次數(shù):
  • HTML閱讀次數(shù):
  • 引用次數(shù):
歷史
  • 收稿日期:
  • 最后修改日期:
  • 錄用日期:
  • 在線發(fā)布日期: 2012-03-17
  • 出版日期:
易福门压力变送器| 上海泳池设备| 免疫球蛋白国际标准品| 一次性预灌装表面接触碟| 单晶硅压力变送器| 船用控制电缆| 电动执行器| 便携式光化学测氧仪| 南京| 电能表校验仪| C80微量热仪| 温室育苗床| 德国SPIRSTAR| PCB力锤传感器| 球形补偿器| 静电除尘电源| 恒温恒湿机.恒温恒湿柜.防潮柜.氮气柜| 美国菲思图| 冷热冲击试验箱| 酶底物法大肠菌群检测试剂| 四氟补偿器| 全自动真空上料机| 打包带设备和金属波纹管设备供应商| 新能源电缆设备| 油墨印刷废气处理设备| 数显测力计| 一步法Elisa试剂盒| 船用电动执行器| 电池防爆| 盐雾试验机| 平口螺旋接地线| Teknova试剂盒| 风电偏航制动器摩擦片| 仪器仪表租赁| 黄曲霉检测试剂| 环境空气温室气体分析仪| 插入式粉尘检测仪| 景观设计| 高精度共晶粘片| 油墨印刷废气处理设备| 标准热电偶|